Home10"W x 4"H

10"W x 4"H

Item No:Nominal
Size
Size
(Duct Opening)
ModelNeck
Size
Actual
Size
MaterialOuter
Dimensions
ColorTypeBulk PricingOrder
12-1011-2021-4950+100+
210202-110x4 2-Way White Steel Air Supply Register, Directional Register Vent Cover for Sidewall Or Ceiling 10x4 2-Way White Steel Air Supply Register, Directional Register Vent Cover for Sidewall Or Ceiling10"W x 4"HSteel11-3/4"W X 5-3/4"HWhite$6.09$5.79$5.67$5.55$5.49
93 in stock
210103-210x4 3-Way White Aluminum Adjustable Curved Blade Supply Register, Air Vent Cover with Damper for Sidewall Or Ceiling 10x4 3-Way White Aluminum Adjustable Curved Blade Supply Register, Air Vent Cover with Damper for Sidewall Or Ceiling10"W x 4"HAluminum11-3/4"W X 5-3/4"HWhite$22.49$21.37$20.92$20.47$20.25
26 in stock
210202-1610x4 2-Way Black Steel Air Supply Register, Directional Register Vent Cover for Sidewall Or Ceiling 10x4 2-Way Black Steel Air Supply Register, Directional Register Vent Cover for Sidewall Or Ceiling10"W x 4"HSteel11-3/4"W X 5-3/4"HBlack$11.99$11.40$11.04$10.68$10.20
223 in stock
210203-110x4 3-Way White Steel Air Supply Register, Directional Register Vent Cover for Sidewall Or Ceiling 10x4 3-Way White Steel Air Supply Register, Directional Register Vent Cover for Sidewall Or Ceiling10"W x 4"HSteel11-3/4"W X 5-3/4"HWhiteEXTRA 10%$6.44$5.79$6.12$5.51$5.99$5.39$5.87$5.27$5.80$5.22
274 in stock
510101-214x10 White Steel Floor Register, Walkable Heavy-Duty Louvered Vent Cover with Damper 4x10 White Steel Floor Register, Walkable Heavy-Duty Louvered Vent Cover with Damper4"W x 10"HSteel5-3/4"W X 11-1/2"HWhiteEXTRA 15%$7.93$6.74$7.54$6.41$7.38$6.27$7.22$6.14$7.14$6.07
845 in stock
510101-124x10 Brown Steel Floor Register, Walkable Heavy-Duty Louvered Vent Cover with Damper 4x10 Brown Steel Floor Register, Walkable Heavy-Duty Louvered Vent Cover with Damper4"W x 10"HSteel5-3/4"W X 11-1/2"HBrown$9.39$8.93$8.74$8.55$8.46
130 in stock
210400-110x4 Black Steel Adjustable Supply Register, Air Vent Cover with Damper for Sidewall Or Ceiling 10x4 Black Steel Adjustable Supply Register, Air Vent Cover with Damper for Sidewall Or Ceiling10"W x 4"HSteel11-3/4"W X 5-3/4"HBlack$17.09$16.24$15.90$15.56$15.39
206 in stock
520101-10Fits 4x10 or 10x4 White Toe Kick Vent Cover, Under Cabinet Toe Space Fits 4x10 or 10x4 White Toe Kick Vent Cover, Under Cabinet Toe Space4"W x 10"HSteel5-3/8"W X 11-3/8"HWhite$5.89$5.31$5.13$4.95$4.72
53 in stock
220101-510x4 White Aluminum Linear 2-Slot Diffuser, Slim Modern AC Vent Cover for Wall, Ceiling & Floor 10x4 White Aluminum Linear 2-Slot Diffuser, Slim Modern AC Vent Cover for Wall, Ceiling & Floor10"W x 4"HAluminum11-3/4"W X 5-7/8"HWhite$28.59$27.17$26.59$26.02$25.74
110108-210x4 White Aluminum Rust-Free Return Air Grille, High-Airflow HVAC Cold Air Intake for Wall & Ceiling 10x4 White Aluminum Rust-Free Return Air Grille, High-Airflow HVAC Cold Air Intake for Wall & Ceiling10"W x 4"HAluminum11-13/16"W X 5-13/16"HWhiteEXTRA 10%$24.06$21.65$22.86$20.57$22.38$20.14$21.90$19.71$21.66$19.49
277 in stock
220101-2710x4 Black Aluminum Linear 2-Slot Diffuser, Slim Modern AC Vent Cover for Wall, Ceiling & Floor 10x4 Black Aluminum Linear 2-Slot Diffuser, Slim Modern AC Vent Cover for Wall, Ceiling & Floor10"W x 4"HAluminum11-3/4"W X 5-7/8"HBlack$40.59$38.57$37.75$36.94$36.54
210203-2110x4 3-Way Black Steel Air Supply Register, Directional Register Vent Cover for Sidewall Or Ceiling 10x4 3-Way Black Steel Air Supply Register, Directional Register Vent Cover for Sidewall Or Ceiling10"W x 4"HSteel11-3/4"W X 5-3/4"HBlack$29.98$28.49$27.59$26.69$25.49

10" x 4" Vent Covers, Registers and Grilles

A 10 by 4 vent cover fits a duct opening that measures 10 inches by 4 inches, and its face runs about 2 inches larger than the opening in each direction so the cut edge stays hidden.

Everything on this page is built for that one opening, on both sides of the system: registers and diffusers that blow air into the room, and grilles that pull room air back into the duct. Pick the row that matches your opening, then choose the material and the face.

Which 10" x 4" Vent Should You Order?

Family in this size What the opening does Where it mounts Ordered by Pick it when you need
Flat Stamped Steel Supply Registers Blows air out Wall or ceiling Duct opening size, width first A plain stamped face, the lowest cost way to cover a supply opening
Aluminum Adjustable Curved Blade Supply Registers Blows air out Wall or ceiling Duct opening size, width first A long throw plus adjustment, in aluminum for damp rooms
Steel Adjustable Supply Registers Blows air out Wall or ceiling Duct opening size, width first Blades that aim the air, with a damper to close the opening
Aluminum Bar Return Grilles Pulls air in Wall or ceiling Duct opening size, width first A bar face in aluminum, for a cleaner look on a return
Aluminum Linear Slot Diffusers Blows air out Wall, ceiling or floor Face length and slot count A slim continuous line instead of a rectangle
Steel Floor Supply Registers Blows air out Floor Opening size, shorter side listed first A floor opening that gets walked on, with a damper to balance the room
Steel Toe Kick Registers Blows air out Kick space under a cabinet Opening size, shorter side listed first The 2 inch and 4 inch heights a kick space allows
  1. If you are not sure which half of the table you are in, hold a tissue to the opening with the system running: pushed away means supply, pulled against the opening means return.
  2. If the opening is in the floor, the 10 by 4 pair is interchangeable, because floor and toe kick registers drop into a flat opening and can be rotated. On a wall or a ceiling it is not: those are listed width first.
  3. If the room stays damp, such as a bathroom or a laundry, choose aluminum rather than painted steel, because aluminum does not rust.
  4. If you are replacing a cover you already have, measure the duct opening behind it, because the face you are holding is about 2 inches larger than the opening in each direction.

How Do You Confirm a 10" x 4" Will Fit?

Measure the duct opening itself, width then height, and compare it with the listed size rather than with the old cover. Wall and ceiling units are listed width first, so the order of the two numbers matters. Floor and toe kick registers list the shorter side first and drop into a flat opening, so they can be rotated. The outer face runs about 2 inches larger than the opening in each direction. Full method: how to measure a vent opening. To check whether this size carries the airflow the room needs, use the CFM sizer.

What Drives the Price in This Size?

Within one size the price moves on three things: the material, whether the unit carries a damper or an adjustable core, and how the face is built. Steel and aluminum are priced differently at the same size, a damper adds parts, and an eggcrate, bar or slot face is built differently from a stamped one. Current prices sit on the product cards on this page.

Common Questions About 10" x 4" Vent Covers

What size duct opening does a 10 by 4 vent cover fit?

A 10 by 4 vent cover fits a duct opening measuring 10 inches by 4 inches. The listed size is always the opening, not the face, so measure the hole in the wall, ceiling or floor rather than the cover you are removing.

What is the actual face size of a 10 by 4 vent cover?

The outer face runs about 2 inches larger than the opening in each direction, so a 10 by 4 unit covers a 10 by 4 opening with an overlap that hides the cut edge. The exact overhang is on each product listing.

Is a 10 by 4 the same as a 4 by 10?

On a wall or a ceiling, no: those are listed width first and the blades run the other way, so the two are different parts. On a floor, yes: floor registers drop into a flat opening and can be rotated.