Home12"W x 2"H

12"W x 2"H

Item No:Nominal
Size
Size
(Duct Opening)
ModelNeck
Size
Actual
Size
MaterialOuter
Dimensions
ColorTypeBulk PricingOrder
12-1011-2021-4950+100+
520101-15Fits 2x12 or 12x2 Gray Toe Kick Vent Cover, Under Cabinet Toe Space Fits 2x12 or 12x2 Gray Toe Kick Vent Cover, Under Cabinet Toe Space2"W x 12"HSteel3-3/8"W X 13-3/8"HGray$7.05$6.35$6.14$5.93$5.64
63 in stock
520101-12Fits 2x12 or 12x2 White Toe Kick Vent Cover, Under Cabinet Toe Space Fits 2x12 or 12x2 White Toe Kick Vent Cover, Under Cabinet Toe Space2"W x 12"HSteel3-3/8"W X 13-3/8"HWhite$10.69$9.63$9.31$8.98$8.56
161 in stock
510101-92x12 Brown Steel Floor Register, Walkable Heavy-Duty Louvered Vent Cover with Damper 2x12 Brown Steel Floor Register, Walkable Heavy-Duty Louvered Vent Cover with Damper2"W x 12"HSteel3-3/4"W X 13-1/2"HBrown$6.09$5.79$5.67$5.55$5.49
520101-5Fits 2x12 or 12x2 Brown Toe Kick Vent Cover, Under Cabinet Toe Space Fits 2x12 or 12x2 Brown Toe Kick Vent Cover, Under Cabinet Toe Space2"W x 12"HSteel3-3/8"W X 13-3/8"HBrown$10.59$9.54$9.22$8.90$8.48
92 in stock
220101-112x2 White Aluminum Linear 1-Slot Diffuser, Slim Modern AC Vent Cover for Wall, Ceiling & Floor 12x2 White Aluminum Linear 1-Slot Diffuser, Slim Modern AC Vent Cover for Wall, Ceiling & Floor12"W x 2"HAluminum13-3/4"W X 3-7/8"HWhite$27.19$25.84$25.29$24.75$24.48

12" x 2" Vent Covers, Registers and Grilles

A 12 by 2 vent cover fits a duct opening that measures 12 inches by 2 inches, and its face runs about 2 inches larger than the opening in each direction so the cut edge stays hidden.

Everything on this page is built for that one opening, on the supply side of the system. Pick the row that matches your opening, then choose the material and the face.

Which 12" x 2" Vent Should You Order?

Family in this size What the opening does Where it mounts Ordered by Pick it when you need
Aluminum Linear Slot Diffusers Blows air out Wall, ceiling or floor Face length and slot count A slim continuous line instead of a rectangle
Steel Floor Supply Registers Blows air out Floor Opening size, shorter side listed first A floor opening that gets walked on, with a damper to balance the room
Steel Toe Kick Registers Blows air out Kick space under a cabinet Opening size, shorter side listed first The 2 inch and 4 inch heights a kick space allows
  1. If the opening is in the floor, the 12 by 2 pair is interchangeable, because floor and toe kick registers drop into a flat opening and can be rotated. On a wall or a ceiling it is not: those are listed width first.
  2. If the room stays damp, such as a bathroom or a laundry, choose aluminum rather than painted steel, because aluminum does not rust.
  3. If you are replacing a cover you already have, measure the duct opening behind it, because the face you are holding is about 2 inches larger than the opening in each direction.

How Do You Confirm a 12" x 2" Will Fit?

Measure the duct opening itself, width then height, and compare it with the listed size rather than with the old cover. Wall and ceiling units are listed width first, so the order of the two numbers matters. Floor and toe kick registers list the shorter side first and drop into a flat opening, so they can be rotated. The outer face runs about 2 inches larger than the opening in each direction. Full method: how to measure a vent opening. To check whether this size carries the airflow the room needs, use the CFM sizer.

What Drives the Price in This Size?

Within one size the price moves on three things: the material, whether the unit carries a damper or an adjustable core, and how the face is built. Steel and aluminum are priced differently at the same size, a damper adds parts, and an eggcrate, bar or slot face is built differently from a stamped one. Current prices sit on the product cards on this page.

Common Questions About 12" x 2" Vent Covers

What size duct opening does a 12 by 2 vent cover fit?

A 12 by 2 vent cover fits a duct opening measuring 12 inches by 2 inches. The listed size is always the opening, not the face, so measure the hole in the wall, ceiling or floor rather than the cover you are removing.

What is the actual face size of a 12 by 2 vent cover?

The outer face runs about 2 inches larger than the opening in each direction, so a 12 by 2 unit covers a 12 by 2 opening with an overlap that hides the cut edge. The exact overhang is on each product listing.

Is a 12 by 2 the same as a 2 by 12?

On a wall or a ceiling, no: those are listed width first and the blades run the other way, so the two are different parts. On a floor, yes: floor registers drop into a flat opening and can be rotated.