Home16"W x 25"H

16"W x 25"H

Item No:Nominal
Size
Size
(Duct Opening)
ModelNeck
Size
Actual
Size
MaterialOuter
Dimensions
ColorTypeBulk PricingOrder
12-1011-2021-4950+100+
110101-2516x25 White Steel Return Air Grille, High-Airflow HVAC Cold Air Intake for Wall & Ceiling 16x25 White Steel Return Air Grille, High-Airflow HVAC Cold Air Intake for Wall & Ceiling16"W x 25"HSteel17-3/4"W X 26-3/4"HWhite$21.79$20.71$20.27$19.83$19.62
3 in stock
110203-816x25 White Steel Return Air Filter Grille, Removable Door, for 1-Inch Filters 16x25 White Steel Return Air Filter Grille, Removable Door, for 1-Inch Filters16"W x 25"HFilter-readySteel18-5/8"W X 27-5/8"HWhite$34.19Filter-ready$32.49$32.49$32.49$32.49
15 in stock
110213-716x25 White Steel Return Air Filter Grille, Filter Included, Removable Door 16x25 White Steel Return Air Filter Grille, Filter Included, Removable Door16"W x 25"HFilter includedSteel18-5/8"W X 27-5/8"HWhite$39.09Filter included$37.14$36.36$35.58$35.19
4 in stock
110201-616x25 White Steel Return Air Filter Grille, Fixed Hinged, for 1-Inch Filters 16x25 White Steel Return Air Filter Grille, Fixed Hinged, for 1-Inch Filters16"W x 25"HFixed hingedFilter-readySteel18-5/8"W X 27-5/8"HWhite$35.59Fixed hingedFilter-ready$33.82$33.82$33.82$33.82
123 in stock
110204-3516x25 White Aluminum Eggcrate Return Air Filter Grille, Removable Door 16x25 White Aluminum Eggcrate Return Air Filter Grille, Removable Door16"W x 25"HAluminum18-1/4"W X 27-1/4"HWhite$106.99$101.65$98.44$95.23$90.95
22 in stock
110202-1216x25 White Steel Return Air Filter Grille, Removable Door, Plastic Latches, for 1-Inch Filters 16x25 White Steel Return Air Filter Grille, Removable Door, Plastic Latches, for 1-Inch Filters16"W x 25"HFilter-readySteel18-5/8"W X 27-5/8"HWhite$32.09Filter-ready$30.49$30.49$30.49$30.49
8 in stock

16" x 25" Vent Covers, Registers and Grilles

A 16 by 25 vent cover fits a duct opening that measures 16 inches by 25 inches, and its face runs about 2 inches larger than the opening in each direction so the cut edge stays hidden. Return air filter grilles overlap more than that: about 2-5/8 inches in steel and about 2-1/4 inches in the aluminum eggcrate style, because the frame has to hold the filter.

Everything on this page is built for that one opening, on the return side of the system. Pick the row that matches your opening, then choose the material and the face.

Which 16" x 25" Vent Should You Order?

Family in this size What the opening does Where it mounts Ordered by Pick it when you need
Steel Return Filter Grilles, Removable Door Pulls air in Wall or ceiling Filter size, not face size The filter to sit at the grille, with a door that lifts off
Flat Stamped Steel Return Grilles Pulls air in Wall or ceiling Duct opening size, width first A plain return face with no damper
Steel Return Filter Grilles, Removable Door & Filter Included Pulls air in Wall or ceiling Filter size, not face size A filter grille that arrives with the filter
Steel Return Filter Grilles, Fixed Hinged Door Pulls air in Wall or ceiling Filter size, not face size A filter grille whose door stays hinged to the frame
Aluminum Eggcrate Return Filter Grilles Pulls air in Wall or ceiling Filter size, not face size An eggcrate face that also holds the filter
  1. If the filter sits behind the grille rather than at the furnace, order a return filter grille, and remember that the size on a filter grille is the filter it holds, not the duct opening.
  2. If the opening is in a wall or a ceiling, order it width first: a 16 by 25 and a 25 by 16 are different parts and the blades run the other way.
  3. If the room stays damp, such as a bathroom or a laundry, choose aluminum rather than painted steel, because aluminum does not rust.
  4. If you are replacing a cover you already have, measure the duct opening behind it, because the face you are holding is about 2 inches larger than the opening in each direction.

How Do You Confirm a 16" x 25" Will Fit?

Measure the duct opening itself, width then height, and compare it with the listed size rather than with the old cover. Wall and ceiling units are listed width first, so the order of the two numbers matters. The outer face runs about 2 inches larger than the opening in each direction. Return air filter grilles overlap more than that: about 2-5/8 inches in steel and about 2-1/4 inches in the aluminum eggcrate style, because the frame has to hold the filter. Full method: how to measure a vent opening. To check whether this size carries the airflow the room needs, use the CFM sizer.

What Drives the Price in This Size?

Within one size the price moves on three things: the material, whether the unit carries a damper or an adjustable core, and how the face is built. Steel and aluminum are priced differently at the same size, a damper adds parts, and an eggcrate, bar or slot face is built differently from a stamped one. Current prices sit on the product cards on this page.

Common Questions About 16" x 25" Vent Covers

What size duct opening does a 16 by 25 vent cover fit?

A 16 by 25 vent cover fits a duct opening measuring 16 inches by 25 inches. The listed size is always the opening, not the face, so measure the hole in the wall, ceiling or floor rather than the cover you are removing.

What is the actual face size of a 16 by 25 vent cover?

The outer face runs about 2 inches larger than the opening in each direction, so a 16 by 25 unit covers a 16 by 25 opening with an overlap that hides the cut edge. The exact overhang is on each product listing. Return air filter grilles overlap more than that: about 2-5/8 inches in steel and about 2-1/4 inches in the aluminum eggcrate style, because the frame has to hold the filter.

Is a 16 by 25 the same as a 25 by 16?

On a wall or a ceiling, no: those are listed width first and the blades run the other way, so the two are different parts.

Does the 16 by 25 size on a filter grille mean the duct or the filter?

On a return filter grille the listed size is the filter it holds, so a 16 by 25 filter grille takes a 16 by 25 filter. Plain return grilles and supply registers are listed by the duct opening instead.