Home16"W x 4"H

16"W x 4"H

Item No:Nominal
Size
Size
(Duct Opening)
ModelNeck
Size
Actual
Size
MaterialOuter
Dimensions
ColorTypeBulk PricingOrder
12-1011-2021-4950+100+
210400-1616x4 White Steel Adjustable Supply Register, Air Vent Cover with Damper for Sidewall Or Ceiling 16x4 White Steel Adjustable Supply Register, Air Vent Cover with Damper for Sidewall Or Ceiling16"W x 4"HSteel17-3/4"W X 5-3/4"HWhite$32.67$31.04$31.04$31.04$31.04
16 in stock
421108-1116x4 White Aluminum Adjustable Supply Register, Rust-Proof Supply Grille for Wall & Ceiling 16x4 White Aluminum Adjustable Supply Register, Rust-Proof Supply Grille for Wall & Ceiling16"W x 4"HAluminum17-3/4"W X 5-3/4"HWhiteEXTRA 10%$35.88$32.29$34.09$30.68$33.37$30.03$32.66$29.39$32.30$29.07
96 in stock

16" x 4" Vent Covers, Registers and Grilles

A 16 by 4 vent cover fits a duct opening that measures 16 inches by 4 inches, and its face runs about 2 inches larger than the opening in each direction so the cut edge stays hidden.

Everything on this page is built for that one opening, on the supply side of the system. Pick the row that matches your opening, then choose the material and the face.

Which 16" x 4" Vent Should You Order?

Family in this size What the opening does Where it mounts Ordered by Pick it when you need
Steel Adjustable Supply Registers Blows air out Wall or ceiling Duct opening size, width first Blades that aim the air, with a damper to close the opening
Aluminum Adjustable Supply Registers Blows air out Wall or ceiling Duct opening size, width first Adjustment in aluminum, for bathrooms, laundries and coastal houses
  1. If the opening is in a wall or a ceiling, order it width first: a 16 by 4 and a 4 by 16 are different parts and the blades run the other way.
  2. If the room stays damp, such as a bathroom or a laundry, choose aluminum rather than painted steel, because aluminum does not rust.
  3. If you are replacing a cover you already have, measure the duct opening behind it, because the face you are holding is about 2 inches larger than the opening in each direction.

How Do You Confirm a 16" x 4" Will Fit?

Measure the duct opening itself, width then height, and compare it with the listed size rather than with the old cover. Wall and ceiling units are listed width first, so the order of the two numbers matters. The outer face runs about 2 inches larger than the opening in each direction. Full method: how to measure a vent opening. To check whether this size carries the airflow the room needs, use the CFM sizer.

What Drives the Price in This Size?

Within one size the price moves on three things: the material, whether the unit carries a damper or an adjustable core, and how the face is built. Steel and aluminum are priced differently at the same size, a damper adds parts, and an eggcrate, bar or slot face is built differently from a stamped one. Current prices sit on the product cards on this page.

Common Questions About 16" x 4" Vent Covers

What size duct opening does a 16 by 4 vent cover fit?

A 16 by 4 vent cover fits a duct opening measuring 16 inches by 4 inches. The listed size is always the opening, not the face, so measure the hole in the wall, ceiling or floor rather than the cover you are removing.

What is the actual face size of a 16 by 4 vent cover?

The outer face runs about 2 inches larger than the opening in each direction, so a 16 by 4 unit covers a 16 by 4 opening with an overlap that hides the cut edge. The exact overhang is on each product listing.

Is a 16 by 4 the same as a 4 by 16?

On a wall or a ceiling, no: those are listed width first and the blades run the other way, so the two are different parts.