Item # 510101-14
| Bulk Pricing | ||||
|---|---|---|---|---|
| 2-10 | 11-20 | 21-49 | 50+ | 100+ |
| $16.49 | $15.52 | $14.55 | $13.58 | |
The 4"W x 14"H brown steel floor register carries supply air into the room through a floor opening. Powder-coated steel resists dents and rust for years of use, a stronger choice than lightweight plastic covers. A built-in damper adjusts or shuts the airflow, so comfort can be set room by room. Select this floor register by its duct opening size, not the overall face size, so it seats correctly on the first fit.
| Product type | Floor Register |
| Airflow function | Supply air |
| Nominal opening | 4"W x 14"H |
| Overall face dimensions | 5-3/4"W X 15-1/2"H |
| Material | Steel |
| Finish | Brown |
| Mounting location | Floor |
| Airflow control | Adjustable damper |
| Order by | Duct Opening |
| Pack quantity | 1 |
| MPN | 510101-14 |
| Brand | AirGrilles.com |
Choose this floor register if you need an adjustable supply-air vent for a floor opening. This floor register carries supply air and mounts on floor surfaces. It is not designed for exterior or outdoor use, dryer exhaust venting or use as a filter-holding return grille. Confirm the airflow function against your HVAC layout before ordering.
Remove the existing vent and measure the width and height of the duct opening, not the outer face of the old cover. Match those two numbers to the nominal size above. The overall face measures 5-3/4"W X 15-1/2"H.
Set the floor register into the floor opening so the face rests level with the floor. No screws are required; the register drops in and its flange keeps it seated. Lift it out by the face for cleaning whenever needed.
Ductwork, wall anchors, and installation tools are not included.
Clean the floor register with a soft, damp cloth and mild soap. Avoid abrasive chemicals that can damage the brown finish. Dry the surface to keep moisture off the metal.
Use this comparison to confirm the floor register matches your opening and airflow need.
| Option | Best for | Material | Installation |
|---|---|---|---|
| This floor register | Floor supply openings | Steel | Floor |
| Return air grille | Return-air openings | Steel | Wall or ceiling |
| Wall/ceiling supply register | Wall or ceiling supply openings | Steel | Wall or ceiling |
| Duct Size (in) | Ak (sq ft) | Metric | Face Velocity (FPM) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 300.0 | 400.0 | 500.0 | 600.0 | 700.0 | 800.0 | 900.0 | 1000.0 | |||
| Pressure Loss (in. w.g.) | all sizes | 0.004 | 0.008 | 0.016 | 0.024 | 0.028 | 0.04 | 0.052 | 0.06 | |
| 2×10 | 0.094 | Air Volume (CFM) | 28 | 38 | 47 | 56 | 66 | 75 | 85 | 94 |
| Spread (ft) | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | ||
| Throw (ft) | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | ||
| 2×12 | 0.110 | Air Volume (CFM) | 33 | 44 | 55 | 66 | 77 | 88 | 99 | 110 |
| Spread (ft) | 4 | 6 | 6 | 7 | 8 | 9 | 10 | 11 | ||
| Throw (ft) | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | ||
| 2×14 | 0.125 | Air Volume (CFM) | 38 | 50 | 63 | 75 | 88 | 100 | 113 | 125 |
| Spread (ft) | 4 | 6 | 7 | 7 | 8 | 10 | 11 | 12 | ||
| Throw (ft) | 5 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | ||
| 3×10 | 0.137 | Air Volume (CFM) | 41 | 55 | 69 | 82 | 96 | 110 | 123 | 137 |
| Spread (ft) | 4 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | ||
| Throw (ft) | 5 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | ||
| 4×8 | 0.150 | Air Volume (CFM) | 45 | 60 | 75 | 90 | 105 | 120 | 135 | 150 |
| Spread (ft) | 4 | 5 | 7 | 8 | 9 | 10 | 11 | 13 | ||
| Throw (ft) | 6 | 7 | 8 | 10 | 11 | 12 | 13 | 14 | ||
| 4×10 | 0.170 | Air Volume (CFM) | 51 | 68 | 85 | 102 | 119 | 136 | 153 | 170 |
| Spread (ft) | 5 | 6 | 7 | 8 | 10 | 11 | 13 | 15 | ||
| Throw (ft) | 6 | 7 | 9 | 11 | 12 | 13 | 15 | 17 | ||
| 4×12 / 6×8 | 0.200 | Air Volume (CFM) | 60 | 80 | 100 | 120 | 140 | 160 | 180 | 200 |
| Spread (ft) | 6 | 7 | 9 | 11 | 12 | 14 | 15 | 17 | ||
| Throw (ft) | 5 | 6 | 8 | 9 | 10 | 11 | 13 | 14 | ||
| 4×14This model | 0.230 | Air Volume (CFM) | 69 | 92 | 115 | 138 | 161 | 184 | 207 | 230 |
| Spread (ft) | 7 | 8 | 10 | 11 | 13 | 16 | 17 | 19 | ||
| Throw (ft) | 6 | 7 | 8 | 10 | 11 | 13 | 14 | 15 | ||
| 6×10 | 0.247 | Air Volume (CFM) | 74 | 99 | 124 | 148 | 173 | 198 | 222 | 247 |
| Spread (ft) | 6 | 8 | 9 | 12 | 13 | 15 | 17 | 19 | ||
| Throw (ft) | 5 | 7 | 8 | 10 | 11 | 13 | 14 | 15 | ||
| 6×12 | 0.285 | Air Volume (CFM) | 86 | 114 | 143 | 171 | 200 | 228 | 257 | 285 |
| Spread (ft) | 7 | 9 | 10 | 13 | 15 | 17 | 19 | 22 | ||
| Throw (ft) | 6 | 8 | 9 | 11 | 12 | 15 | 16 | 18 | ||
| 6×14 | 0.335 | Air Volume (CFM) | 101 | 134 | 168 | 201 | 235 | 268 | 302 | 335 |
| Spread (ft) | 8 | 9 | 11 | 13 | 16 | 18 | 20 | 22 | ||
| Throw (ft) | 6 | 8 | 10 | 12 | 13 | 15 | 17 | 18 | ||
| 8×14 | 0.406 | Air Volume (CFM) | 122 | 162 | 203 | 244 | 284 | 325 | 365 | 406 |
| Spread (ft) | 9 | 10 | 11 | 14 | 17 | 18 | 21 | 23 | ||
| Throw (ft) | 7 | 8 | 10 | 12 | 13 | 15 | 17 | 19 | ||