A 14 by 6 vent cover fits a duct opening that measures 14 inches by 6 inches, and its face runs about 2 inches larger than the opening in each direction so the cut edge stays hidden. A return air filter grille overlaps more than that, about 2-5/8 inches, because the frame has to hold the filter.
Everything on this page is built for that one opening, on both sides of the system: registers and diffusers that blow air into the room, and grilles that pull room air back into the duct. Pick the row that matches your opening, then choose the material and the face.
| Family in this size | What the opening does | Where it mounts | Ordered by | Pick it when you need |
|---|---|---|---|---|
| Flat Stamped Steel Supply Registers | Blows air out | Wall or ceiling | Duct opening size, width first | A plain stamped face, the lowest cost way to cover a supply opening |
| Aluminum Adjustable Curved Blade Supply Registers | Blows air out | Wall or ceiling | Duct opening size, width first | A long throw plus adjustment, in aluminum for damp rooms |
| Steel Adjustable Supply Registers | Blows air out | Wall or ceiling | Duct opening size, width first | Blades that aim the air, with a damper to close the opening |
| Steel Curved Blade Supply Registers | Blows air out | Wall or ceiling | Duct opening size, width first | A longer throw across the room |
| Aluminum Adjustable Supply Registers | Blows air out | Wall or ceiling | Duct opening size, width first | Adjustment in aluminum, for bathrooms, laundries and coastal houses |
| Flat Stamped Steel Return Grilles | Pulls air in | Wall or ceiling | Duct opening size, width first | A plain return face with no damper |
| Steel Return Filter Grilles, Removable Door | Pulls air in | Wall or ceiling | Filter size, not face size | The filter to sit at the grille, with a door that lifts off |
| Aluminum Bar Return Grilles | Pulls air in | Wall or ceiling | Duct opening size, width first | A bar face in aluminum, for a cleaner look on a return |
| Aluminum Linear Slot Diffusers | Blows air out | Wall, ceiling or floor | Face length and slot count | A slim continuous line instead of a rectangle |
| Steel Floor Supply Registers | Blows air out | Floor | Opening size, shorter side listed first | A floor opening that gets walked on, with a damper to balance the room |
| Steel Baseboard Supply Registers | Blows air out | Along a baseboard | Run length | A long low opening at floor level |
| Steel Baseboard Return Grilles | Pulls air in | Along a baseboard | Run length | A return at floor level |
| Triangle Corner Baseboard Supply Register | Blows air out | Baseboard corner | Run length | An angled corner at floor level |
| Steel Triangle Baseboard Return Grilles | Pulls air in | Baseboard corner | Run length | A return that turns a corner |
Measure the duct opening itself, width then height, and compare it with the listed size rather than with the old cover. Wall and ceiling units are listed width first, so the order of the two numbers matters. Floor and toe kick registers list the shorter side first and drop into a flat opening, so they can be rotated. The outer face runs about 2 inches larger than the opening in each direction. A return air filter grille overlaps more than that, about 2-5/8 inches, because the frame has to hold the filter. Full method: how to measure a vent opening. To check whether this size carries the airflow the room needs, use the CFM sizer.
Within one size the price moves on three things: the material, whether the unit carries a damper or an adjustable core, and how the face is built. Steel and aluminum are priced differently at the same size, a damper adds parts, and an eggcrate, bar or slot face is built differently from a stamped one. Current prices sit on the product cards on this page.
A 14 by 6 vent cover fits a duct opening measuring 14 inches by 6 inches. The listed size is always the opening, not the face, so measure the hole in the wall, ceiling or floor rather than the cover you are removing.
The outer face runs about 2 inches larger than the opening in each direction, so a 14 by 6 unit covers a 14 by 6 opening with an overlap that hides the cut edge. The exact overhang is on each product listing. A return air filter grille overlaps more than that, about 2-5/8 inches, because the frame has to hold the filter.
On a wall or a ceiling, no: those are listed width first and the blades run the other way, so the two are different parts. On a floor, yes: floor registers drop into a flat opening and can be rotated.
On a return filter grille the listed size is the filter it holds, so a 14 by 6 filter grille takes a 14 by 6 filter. Plain return grilles and supply registers are listed by the duct opening instead.
Thanks for subscribing!
This email has been registered!
Order by the duct opening, not the faceplate. Remove the vent and measure the hole behind it, then order that size. Getting it right the first time means no returns, no reorders, and no waiting on the job.